Home › Industry Solutions › Building & Infrastructure
Industry solutions
Building & Infrastructure
Configurable 12/24 V DC power control for building systems, from smoke vents to access control.
The challenge
When the alarm goes off, the vents and doors have to work.
Many of the systems that help people get out of a building safely run on 12 or 24 V DC.
Hard-to-reach equipment
Actuators on high windows, louvres and smoke vents are hard to get to for inspection and repair.
Fuses, relays and terminals
Smoke control inspections check fuses, isolators, relays, contactors, cables and terminals. Each one is a point that can fail.
Faults found late
A failed circuit may not show until the next scheduled test, or until it’s needed.
How Hardwire helps
Configurable DC power control for buildings.
Configurable protection
Per-circuit electronic protection, set to suit each actuator, cable and load.
Programmable logic
Outputs respond to fire alarm signals, wind and rain sensors, timers or a manual override.
Current and fault logging
Output current and trip history can be logged on board, set up to suit, and read on site with a laptop.
Fewer relays and fuses
Solid-state outputs replace banks of relays and fuses in the control cabinet.
Typical applications
Where it’s used in buildings.
Selected 12/24 V DC circuits in commercial and public buildings. Life-safety circuits are designed with the project’s fire engineer, and each circuit is checked for current, inrush and cable rating at installation.
Smoke vents & curtains
12/24 V DC actuators on high-level windows, roof vents and smoke curtains.
Access & doors
Maglocks, strikes and automatic doors, released on alarm.
Louvres & blinds
Motorised louvres and blinds for everyday ventilation and shading.
Car parks & gates
24 V DC barrier and gate operators.
LED & signage
Architectural, facade and sign lighting zones.
Battery & DC backup
Protection and switching inside battery storage systems.
White paper
Smoke vents and 12/24 V actuators
Free white paper
Smoke vents and 12/24 V actuators: protection, testing and records for building owners
What overseas fire investigations and NZ warrant of fitness rules mean for 12/24 V DC smoke control circuits.
We’ll email you the white paper and may follow up once. See our privacy policy.
At Ākau Tangi Sports Centre in Wellington (formerly the ASB Sports Centre), a Hardwire PDM controls the actuators on the high-level windows, so they open and stay open if the fire alarm goes off.
Hardwire Oceania, installation at Ākau Tangi Sports Centre, Kilbirnie, Wellington · Talk to us about your building →
months: how often a building owner must sign, issue and display a building warrant of fitness, covering specified systems such as smoke control.
Source: MBIE, building.govt.nz
Let’s talk about your application.
Our team is here to help you find the right solution.
